Tech Tip: Honda MIL Comes On with DTC P1457 Set

Tech Tip: Honda MIL Comes On with DTC P1457 Set

If you encounter a Honda with the MIL on with DTC P1457 (EVAP control system leakage), this may be caused by the EVAP solenoid valve (fuel vent module) being blocked or restricted. To correct this, install an EVAP solenoid valve kit.

Applies To:

2001-’05 Civic 2/4-door – all

2002-’05 Civic 3-door – all

2003-’05 Civic Hybrid ULEV – all

2002-’04 CR-V – all

Symptom: The MIL comes on with DTC P1457 (EVAP control system leakage).

Probable Cause: The EVAP solenoid valve (fuel vent module) is blocked or restricted.

Corrective Action: Install an EVAP solenoid valve kit.

Parts Information:

EVAP Solenoid Valve Kit: Civic – P/N 06172-S5A-305, CR-V – P/N 06172-S9A-305

Fuel Tank Unit Locknut and Base Gasket: Civic VINs beginning with 1HF or JHM P/N 17046-S5A-A00, Civic VINs beginning with 2HG or SHH P/N 17046-S0X-A30, CR-V P/N 17406-S9A-A00

Fuel Feed Retainer: All models – P/N 17711-S84-004

Fuel Pulsation Damper Washer: CR-V only – P/N 16705-PD1-003
Propeller Shaft Bolts (eight required): CR-V 4WD only – P/N 90113-S10-000

 

Diagnosis:

1. Connect the HDS to the DLC (data link connector) and check for DTCs. Is DTC P1457 stored?

Yes – Clear the DTC, then go to step 2.

No – This service bulletin does not apply; continue with normal troubleshooting.

2. Follow the HDS screen prompts, and do the EVAP Function Test. Did the EVAP solenoid valve pass the test?

Yes – This service bulletin does not apply; continue with normal troubleshooting.

No – If you’re working on a Civic, go to Repair Procedure A. If you’re working on a CR-V, go to Repair Procedure B.

Repair Procedure A:

1. Relieve the fuel pressure.

2. Drain the fuel, then remove the fuel tank.

3. Remove the EVAP solenoid valve (see Fig. 1):fig. 1

– Remove pressure sensor tube B; it will be reused.

– Remove fuel vent tube B; it will not be reused.

– Disconnect fuel vent tube C from the EVAP solenoid valve. The tube will be reused.

– Disconnect the 2P connector from the EVAP solenoid valve.

– Remove the EVAP solenoid valve (two bolts). The bolts will be reused. The valve will not be reused.

4. Attach the tubes and the joint from the kit onto the new EVAP solenoid valve as shown in Fig. 2. fig. 2

5. Install the new EVAP solenoid valve using the original bolts.

6. Connect the original hoses and the new tubes as shown in Fig. 3. fig. 3

7. Reinstall the fuel tank.

8. Reinstall the fuel tank unit with a new base gasket and a new locknut.

9. Reinstall the fuel line to the tank with a new fuel feed retainer.

10. Refill the tank with the fuel you removed in step 2.

Repair Procedure B:

1. Relieve the fuel pressure.

2. Drain the fuel, then remove the fuel tank.

3. Remove the EVAP canister.

4. Remove the EVAP solenoid valve from the EVAP canister (see Fig. 4):fig. 4

– Remove pressure sensor tube B; it will not be reused.

– Remove fuel vent tube C; it will not be reused.

– Remove fuel vent tube D; it will not be reused.

– Disconnect the 2P connector.

– Remove the EVAP solenoid valve bolts. The bolts will be reused.

– Disconnect the remaining hoses connected to the EVAP solenoid valve, then remove the valve. The valve will not be reused.

5. Attach the tubes, the vacuum chamber, the joint and the clips from the kit onto the new EVAP solenoid valve as shown in Fig. 5. fig. 5

6. Install the new EVAP solenoid valve on the EVAP canister using the original bolts.

7. Reinstall the EVAP canister.

8. Connect the original hoses and the new tube as shown in Fig. 6. Fig. 6

9. Reinstall the fuel tank.

10. Reinstall the fuel tank unit with a new base gasket and a new locknut.

11. Reinstall the fuel line to the tank with a new fuel feed retainer.

12. Refill the tank with the fuel you removed in step 2.

Courtesy of ALLDATA.

 

 

 

You May Also Like

Love’s To Debut Hunter Hawkeye XL Alignment System

New heavy-duty system designed to deliver accurate measurements in four minutes or less to debut at five Love’s locations.

Love’s and Hunter Engineering have announced the rollout of Hunter’s new HawkEye® XL alignment system at five Love’s locations.

The new aligner is designed for maximum speed, durability and ease of use for heavy-duty, medium-duty and light-duty vehicles, delivering accurate measurements in four minutes or less.

Catalytic Converter Replacement

Converters must be certified and labeled with the correct codes that are stamped into the shell.

Determining Catalytic Converter Efficiency

Tiny details can limit the life of a catalytic converter.

Stainless Steel Did Not Kill The Exhaust Repair

Direct fit parts can be used to make an effective repair quickly.

Resetting Emissions Monitors After Converter Replacement

Here are the 10 commandments of a catalytic converter replacement handed down from the EPA.

Other Posts

Schaeffler Features Automotive Repair Solutions at AAPEX

Technologies on display feature repair solutions for today and tomorrow’s automotive aftermarket needs.

Meet MEYLE Experts at the Venetian Expo

AAPEX will be held at the Venetian Expo in Las Vegas on October 31-November 2.

MotoRad Celebrates 65 Years at AAPEX 2023

AAPEX 2023 takes place in Las Vegas, Nevada on October 31- November 2.

ASE Fall Testing Registration Open

Those registering by Dec. 31 will have 90 days to schedule an appointment to take their selected ASE tests.